The wall dry–lining insulation shall be Kingspan Kooltherm® K Insulated Dry– lining Board comprising a mm plasterboard facing bonded to ____mm. Kingspan Kooltherm K Super high performance rigid thermoset phenolic insulation; Fibre-free, closed cell insulation core; 3-in-1 insulation, dry-lining and . Kooltherm K17 Insulated Dry-lining Board is an insulated plasterboard for traditional dot and daube plaster adhesive fixing. The tapered edge board enables flat.

Author: Malakasa Mikabar
Country: Romania
Language: English (Spanish)
Genre: Literature
Published (Last): 28 February 2006
Pages: 146
PDF File Size: 7.98 Mb
ePub File Size: 2.23 Mb
ISBN: 916-3-88251-635-6
Downloads: 58960
Price: Free* [*Free Regsitration Required]
Uploader: Baran

Send Us An Enquiry. The fire rating of Kingspan Kooltherm K17 boards when subjected kkooltherm British Standard fire tests, will vary, depending on the particular application. Please note that the reflective surfaces on this product are designed to enhance their thermal performance. It is recommended that mechanical fixings are positioned in the tapered edge of the boards so that they are covered when the board is finished, e. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used.

Drywall screws or, alternatively, galvanised clout nails, long enough to allow a minimum 25 mm penetration of the timber, should be placed at mm centres and not less koolthrem 10 mm from the edges of the board.

Nailable plugs are recommended to complement the plaster dab bond.

mm Kingspan Kooltherm K17 Phenolic Insulation with Plasterboard

Dry Wall Plasterboard View Instructions. Boards are then located against the adhesive dabs and tapped back to align with predetermined guidelines on the floor and ceiling.

Ensure accurate trimming to achieve close butting joints and continuity of insulation. Adhesives containing such solvents should not be used in association with koolther, product. The frame should be set vertically at a maximum of mm centres to coincide with board joints and midpoint of board.

However, it is recommended that any spills be cleaned off fully before the boards are installed. Cutting should be carried out either kokltherm using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs.

  DI - 524M PDF

Cutting Cutting should be carried out either by using a fine toothed saw, or by koootherm with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.

Method of test to determine the classification of the surface spread of flame of products Result – Class 1 rating. Heavy surface mounted fittings will require provision for the fixing load to be applied direct to the supporting wall and not to the K17 in isolation. Tap the board back firmly using a straightedge, ensuring that the vertical koootherm is plumb.

Kingspan Kooltherm K17 Insulated Plasterboard

Mechanical Fixing to Metal Furring Systems K17 Insulated Plasterboard can be fixed by the use of proprietary metal framing systems to brick, block or concrete walls. Modified to include board facings, the boards achieve a resistance far greater than MN. To find out more about the cookies we use, koltherm to change your cookie preferences i.

koolthegm K17 may be used to line ceilings. Click Add to Cart Button. We’re ready to help. It should, therefore, not be used to isolate dampness nor be used in continuously damp or humid conditions. Construction Adhesive Bonding View Instructions.

Kooltherm K17| Insulated Plasterboard | Kingspan | Ireland

If correctly applied, K17 Insulated Wall Board has an indefinite life. However, it is recommended that any spills be cleaned off fully before the boards 1k7 installed.

Boards that have been allowed to get wet should not be used. The ceiling lining should be in position before wall lining commences. Damaged boards or boards that have been in contact with koolgherm solvents or acids should not be used. Kooltherm K17 Insulated Plasterboard. Ensure that safe methods of cleaning are used, as recommended by the suppliers of the spilt liquid.

Timbers must offer a minimum 20 mm support to all four edges of the board. Installation is similar to that of standard plasterboard. Water Vapour Resistance Modified to include board facings, the boards achieve a resistance far greater than MN. Provision for horizontal services behind the board can be made by the use of two pieces of metal framing set no more than mm apart. These must be long enough to allow a minimum 25 mm penetration of the supporting timber, and be placed not less than 10 mm from the edges of the board and be spaced at mm intervals along all supporting timbers.

  ADAM ZBOROWSKI MASA SEGMENTARNY PDF

The rigid phenolic insulation core of K17 Insulated Dry J17 Board will achieve the results given below, which koolyherm it to be classified by the Building Regulations as being Class 0 and as Low Risk by the Technical Standards in Scotland. Presently there are no availability restrictions, apart from manufacturing lead-times and minimum quantity order levels on the j17, 30mm, 70mm, 80mm, mm and mm boards.

Boards should be stored inside a building. Please contact us for more information. Resistance to Solvents The insulation core is koo,therm to short-term contact with petrol and with most dilute acids, alkalis and mineral oils. Wall mounted fittings such as electrical sockets should be fitted so as to take kpoltherm account the additional wall thickness. Test – BS —7: The insulation core is resistant to short—term contact with petrol and with most dilute acids, alkalis and mineral oils.

Continue dry lining in the same manner. Fixing should employ the same method as is used for the plain wall areas.

Click items below for pricing structure. Method of test to determine the classification of the surface spread of flame of products Result – Class 1 rating Test – BS —1: Kingspan Kooltherm K17 Insulated Plasterboard can be applied utilising a variety of traditional or modern dry-lining techniques, to dry and structurally sound walls.

Determination of compression behaviour. Kingspan K17 high specification phenolic foam boards are suitable for use with all cavity masonry wall constructions and some solid walls, and timber frame walls. Mechanical fixings are recommended to complement the adhesive bond.